Magentis and Optima repair since 2000 of release
1. Engines
2. Greasing system
3. Cooling system
4. Control and decrease in toxicity
5. Fuel system
6. Ignition system
7. Coupling
8. Transmission
9. Power shafts, axes
10. Suspension bracket
11. Steering
12. Brake system
13. Body
14. Central air
15. Electric equipment
15.1. Specifications
15.2. Charging system
15.3. Power failure check on a wire connecting the storage battery to the generator (V6 engine)
15.4. Check of the current developed by the generator
15.5. Check of developed tension
15.6. Power failure check on a wire connecting the storage battery to the generator (the engine of 2,0 l)
15.7. Check of the current developed by the generator (the engine of 2,0 l)
15.8. Check of developed tension (the engine of 2,0 l)
15.9. Generator
15.10. Storage battery
15.11. Survey of the storage battery
15.12. Start system
15.13. Removal and starter installation
15.14. Transceiver installation
15.15. Removal and installation of remote control
15.16. Removal and audioblock installation
15.17. Multipurpose switch
15.18. Safety locks
15.19. Combination of devices
15.20. Switch of position of the parking brake
15.21. Heater of back glass
15.22. Screen wiper and stekloomyvatel of a windscreen
15.23. Safety cushions (SRS)
15.24. Precautionary labels
15.25. Safety cushion of the driver and spiral wire
15.26. Safety cushion of the forward passenger
15.27. Search and elimination of malfunctions of system of a charging
15.28. Search and elimination of malfunctions of system of start of the engine
16. Electric circuits
 








canada drug center

15-4-proverka-toka-vyrabatyvaemogo-generatorom.html

15.4. Check of the current developed by the generator

This check allows to define, whether develops the generator a current which is equivalent to rated power.

Preparation for check

 PERFORMANCE ORDER

1. Before test check the following elements:

  • condition of the storage battery established in the car;
  • tension of a belt of a drive of the generator.

The storage battery which is used for check of the current developed by the generator, should be partially discharged. At completely charged battery check cannot be executed because of insufficient loading of the generator.

2. Switch off ignition.
3. Disconnect a wire from the negative plug of the storage battery.
4. Disconnect a wire from the generator plug "B".
5. Connect the ampermeter of a direct current with a limit of measurement of 0-100 A consistently between the plug "B" and the wire disconnected from the generator. Be convinced that negative щуп the ampermeter connected to the wire disconnected from the generator.

Connect wires and щупы the ampermeter very reliably as on a chain the big current will proceed.

6. Connect the voltmeter (0–20 In) between the plug "B" of the generator and "weight". Be convinced that positive щуп the voltmeter connected to the generator plug "B".
7. Connect a tachometer and a wire to the negative plug of the storage battery.

8. Leave a cowl open.

Check

 PERFORMANCE ORDER

1. Check that the scale of the voltmeter is well visible for determination of size of tension. If the voltmeter shows tension 0 In, means, the electric chain connecting the plug "B" of the generator and the negative plug of the storage battery is not closed, the fusible insert or unreliable connection with "weight" fused.
2. Start the engine and include headlights.
3. Include a driving beam of headlights and the heater fan in a mode of the maximum supply of air. Quickly increase frequency of rotation of a cranked shaft of the engine to 2 500 mines-1 and read values on devices, thus the ampermeter will show a current developed by the generator.

After engine start the current of a charging of the storage battery very quickly decreases, therefore this check is necessary for carrying out very quickly.

Result of check

 PERFORMANCE ORDER

1. Indications of the ampermeter should exceed limiting value. If value of a current less limiting value, and a wire connecting an exit of the generator, as it should be, remove the generator from the car and check it.

Limiting value of a current for the generator 95 A : 63,0 And

Limiting value of a current is specified on the plate attached to the case of the generator.

The current developed by the generator, depends on temperature and loading. Therefore for obtaining limiting value of a current partially discharge the storage battery, previously having included headlights on the car with the idle engine.

Limiting value of a current developed by the generator cannot be received, if generator or air temperature the too high.

2. After completion of test of limiting value of the current developed by the generator, transfer the engine to a mode of idling and switch off ignition.
3. Disconnect a wire from the negative plug of the storage battery.
4. Remove a tachometer, the voltmeter and the ampermeter.
5. Connect a wire to the generator plug "B".
6. Connect a wire to the negative plug of the storage battery.


«on a step back
15.3. Power failure check on a wire connecting the storage battery to the generator (V6 engine)
on the following page»
15.5. Check of developed tension